CME Battery Energy Storage Systems (BESS) provide flexible, reliable energy buffering and dispatch for oil & gas, mining, remote water-intake pumping stations, and other off-grid industrial applications.
Based on LiFePO4 (LFP) chemistry, our systems offer 0.5–6.8 MWh per standard container (20HC: 1.5–3.65 MWh; 40HC: 3.4–6.88 MWh), with parallel multi-container arrays scaling to 100+ MWh. Whether replacing diesel gensets for backup, enabling peak shaving and demand management, or providing black-start and frequency regulation, CME BESS delivers fully engineered, deployable solutions.
Automotive-grade LiFePO4 (LFP) cells, ≥6,000–8,000 cycles at 80% DoD (25°C), 10–15 year calendar life. 0.5C (energy) / 1C (fast-response) C-rate options. Multi-level fusing, DC breakers, leakage detection.
Grid-forming (VF) and grid-following (PQ) modes; four-quadrant operation; black-start capable; response <40 ms. Peak efficiency 97.6% (CEC 97.0%), select models >98.8%. 480/600/690 Vac, 50/60 Hz, 3P3W or 3P4W.
Three-tier architecture (slave/master/central). Monitors voltage, current, temperature, SOC, SOH. Cell balancing ±10 mV, thermal-runaway warning, multi-level linked protection. Communication: CANbus, RS485, Modbus.
Load forecasting and price-responsive charge/discharge scheduling. Supports solar-storage coordination, peak-valley arbitrage, demand management, seamless on/off-grid switching. Web & mobile interfaces; Modbus / IEC 104 / DNP3 / IEC 61850.
Forced air cooling (standard, -20 to +60°C discharge) or liquid cooling (high-density 40HC, cell ΔT <5°C, stable to +55°C ambient).
FK-5-1-12 (Novec) / aerosol three-level detection (smoke/temperature/VOC), linked BMS-PCS emergency shutdown. Compliance: IEC 62619, UL 1973, UL 9540A, UN38.3, NFPA 855, IEC 62933.
BESS Containers
*Container size is ultimately determined by the quantity and dimensions of integrated system equipment.
BESS Cabinets
DC-coupled (bidirectional DC/DC for PV direct charge, fewer conversion stages) or AC-coupled (PCS and PV inverter parallel on AC bus; retrofittable to existing PV arrays).
With T&D:
BESS connects to MV/LV AC bus via PCS, working with transformers and switchgear for power distribution. EMS centrally dispatches power flow between PV, storage, and grid, supporting grid-connected/islanded/hybrid mode switching.
Retrofit Path:
For sites with existing diesel gensets, BESS can be added incrementally—cabinet units for smaller sites or container units for larger sites—progressively replacing genset runtime. During transition, diesel and BESS can run in parallel to ensure continuity.