E-mail: sales@cmecn.com

English
  • English
CME Fluid System Solutions Logo
CME microgrid power supply soluti system

Transformers & Substations

Power Distribution & Transformer Systems for Oil, Gas & Mining Operations


CME supplies auxiliary power distribution and transformation solutions that safely bridge generation sources (gensets, PV arrays, BESS) and field loads, including pump skids, solids control systems, MCC cabinets, instrumentation, and camp facilities. 

All units are engineered for hazardous-area compliance and rapid skid-mounted deployment, with no interference to primary mechanical drives. 


We supply field-proven transformer products engineered for remote oil, gas, and mining sites, available in four configurations:

  • General-Purpose Dry-Type Transformers (SCB series, for surface non-hazardous applications)
  • Mining-Grade Flame-Retardant Dry-Type Transformers (KBSG series, Ex d I Mb, for underground/opencast mines)
  • Oil-Immersed (Wet-Type) Transformers (for onshore oil & gas pads, refineries, pipelines)
  • Prefabricated Substations (*Trailer-mounted optional)

General-Purpose Dry-Type Transformers (SCB Series)


Low-loss epoxy-cast units for oil & gas surface facilities, mining surface camps/workshops, and Zone 2 non-hazardous areas

Built with high-permeability grain-oriented silicon steel sheets, processed via fully automated stacking lines with multi-step 45° full-oblique joints and PET-band clamping to minimize no-load loss and acoustic noise. Vacuum-pressure epoxy casting ensures partial discharge <5pC for 30+ year design life.

  • Low Loss & Quiet: No-load loss ~10% better than IEC/GB baseline; AN noise ≤55 dB @ 7m (mid-range).
  • Overload: 20% long-term overload under IP23 without forced-air cooling.
  • Winding: Semi-hard oxygen-free copper, vacuum-cast epoxy; HV 10/35kV, LV 0.4kV (optional 0.69/1.14kV).

Parameter Specification
Capacity Range 30 – 2500 kVA (10kV) / up to 4000 kVA (35kV)
Rated HV 6 / 6.3 / 6.6 / 10 / 11 / 35 kV (±2×2.5% taps)
Rated LV 0.4 kV (optional 0.69 / 1.14 kV for mining surface)
Vector Group Dyn11 / Yyn0
Insulation Class F (155°C) / H (180°C) optional
Cooling AN / AF (forced air)
Protection IP20 / IP30 / IP54 (enclosed)
Standards IEC 60076, GB/T 10228, GB 20052 (Tier 1/2 energy)
CME solar panels and inverters
CME diesel generator set

Mining-Grade Flame-Retardant Dry-Type Transformers (KBSG Series)


Ex d I Mb, mandatory for underground coal/metal mines; also used in opencast high-risk zones

Flame-retardant epoxy-encapsulated windings in stainless-steel corrugated tank enclosure. Optimized for 693V/1200V/3450V secondary to feed shuttle cars, conveyors, dewatering pumps. 

  • Ex d I Mb: Full flame-proof for gaseous mine zones; MA mining safety approval.
  • Compact & Mobile: Rocker wheels / skid base for underground passage.
  • Winding: Copper, vacuum-pressure impregnated; HV 6/10kV.
Parameter Specification
Capacity Range 100 – 4000 kVA
Rated HV 6 / 10 kV (±5% taps)
Rated LV 693V / 1200V / 3450V (mining duty)
Vector Group Yy0 / Dyn11
Short-Circuit Impedance 4% / 4.5% / 5% / 5.5% / 6% (by kVA)
Certification Ex d I Mb, MA (Mining Safety Approval)
Standards IEC 60076, GB/T 8286

Oil-Immersed (Wet-Type) Transformers


Same premium silicon steel core + automated stacking as dry-type; oil immersion further reduces load loss. Tank & conservator pass ±0.05MPa pressure/vacuum leak test; one-piece molded oil-resistant acrylate gaskets with flange-groove mounting.

  • Low Loss: S22 / NX1 energy-tier cores available; no-load loss 8–12% better than GB/IEC baseline at comparable ratings.

  • High-Temp & Overload: Rated -40°C to +55°C ambient; 20% sustained overload capability for peak-demand / seasonal spike periods.
  • Liquid Options: Mineral oil as standard; FR3 natural ester optional for environmentally sensitive or fire-risk sites (e.g., near wellhead processing, pipeline stations).
  • Non-Standard by Project: Capacity, HV grade, tapping mode, and cooling are matched to your load profile, site layout, and regional compliance—rather than fixed SKUs.
Parameter Specification
Capacity 100 kVA – 10 MVA (typical: 500 / 1000 / 2500 / 5000 / 10000)
HV 10 / 35 / 66 / 110 kV (±2×2.5% off-circuit, or on-load tap by spec)
LV 0.4 / 6.3 / 11 kV
Vector Group Dyn11 / Ynd11 (default Dyn11)
Cooling ONAN / ONAF (fan-assist by order)
Insulation Liquid Mineral oil (std) / FR3 natural ester (opt.)
Short-Circuit Impedance 4% / 4.5% / 5% / 5.5% / 6% (by kVA & voltage)
Standards IEC 60076, GB 1094, GB 20052 (Tier 1/2)
CME solar panels and inverters
CME diesel generator set

Prefabricated Substations (Skid-Mounted)


Turnkey distribution, lift-and-drop ready.

Integrates transformer (dry or oil-immersed), HV RMU (SF₆-free optional), LV GGD/combiner, surge protection; trailer-mounted variant available for temporary/mobile sites.

  • Compact: 30–40% footprint vs. brick-built (ref: Zhongpeng 中鹏 case).
  • Weatherproof: Double-seal + drip-groove; IP54, -40°C to +45°C.
  • Smart-Ready: Pre-wired RTUs, temp/RCD monitoring, SCADA uplink.
  • FAT-tested: On-site commissioning cut ~60%.
Parameter Specification
Integrated Components Transformer + HV RMU + LV GGD + Protection
Voltage Rating Up to 35 kV (40.5 kV optional)
Transformer Type Dry (SCB) or Oil-Immersed, per application
Enclosure IP54, anti-corrosion coated steel / sandwich panel
Deployment Skid-mounted, lift-and-drop, ISO-base compatible
Standards IEC 61330, GB/T 17467, CSG/SGCC type-test

Power Distribution Systems


Power distribution is the critical link between generation and field loads—engineered for safe voltage conversion, fault isolation, and hazardous-area compliance.

Component Key Equipment Function
Transformation Core Dry-type (SCB/KBSG) / Oil-Immersed Steps voltage up/down; matches generation to load
HV Switching RMU (Ring Main Unit), Load Break Switch Isolate faults, loop-in/loop-out for site networks
LV Distribution GGD / MCC Panel, Circuit Breakers Distribute to pump skids, MCC, lighting, camp
Protection Surge Arresters, Relay, Grounding Grid Overvoltage, short-circuit, ESD protection
Monitoring RTU, Multi-function Meters, Temp Sensors Remote V/A/Hz/temp telemetry to SCADA
Enclosure & Skid Prefab Substation Housing, Cable Trays Weather/Ex protection, lift-and-drop ready
CME solar panels and inverters

Why Choose CME


1. Application-Correct Selection

Mining → KBSG (mandatory); Oil & gas surface → SCB or Wet-type per site/budget/regulation. No one-size-fits-all.

2. Premium Core & Winding

High-permeability silicon steel + oxygen-free copper + automated stacking/PET clamping (CEEG/TSTY-level process) for low no-load loss and 30-year design life.

3. Hazardous-Area Compliance

Ex d I Mb (mining), Ex d / Ex e for Zone 1/2 oil & gas; IP54+; CSG/SGCC-type prefab substations.

4. One-Stop With Your Pump Skids

Same-point sourcing for skids + power distribution eliminates interface gaps and cuts commissioning time—critical for remote projects.

Take Action


Need Safe, Compliant Power Distribution for Your Remote Site?

Whether it's a KBSG for an underground mine, a wet-type bank for an onshore pad, or a skid-mounted substation with trailer option—CME matches configuration to your load and compliance, not the other way around.

  • Selecting the right transformer for a new mining/oil & gas project?
  • Have existing drawings and need full-component sourcing?
  • Looking for one-stop support for pump skids + power distribution?
Contact CME Sales Engineers for Custom Pump Skid Solutions

Spare Parts


Mud Pumps Spare Parts

Solids Control Spare Parts

Frac & Acidizing Spare Parts

API 610 Pump Spare Parts

Contact Us


+86 182 2980 0688

sales@cmecn.com

No.249 Furong South Road, Changsha, 

Hunan, China


24/7 Technical Support

Copyright © 2025-2028 CME Fluid System Solutions All rights reserved.